Skip to content
HomeAbout usProducts ResourcesBlog Contact
RPA13 Sodium-ion Start-Stop Cell
Sodium-ion cells

RPA13 Sodium-ion Start-Stop Cell

RPA13 sodium-ion start-stop cell from 014 Advanced Material: 13.5 Ah / 42.1 Wh at 3.12 V (2.0–3.6 V window). Aluminium shell with dual large-area terminals, dual vents and full-tab jellyroll. 15C capacity retention 97.1%, operable to -50 °C, 2,000 cycles at 100% DOD, certified to GB 38031.

13.5 Ah / 42.1 Wh15C discharge · 97.1% retentionOperable to -50 °C2,000 cycles @100% DODGB 38031 certifiedAluminium shell + full-tab design
Request a quote

Technical specifications

ModelRPA13 (014 Advanced Material)
ChemistrySodium-ion (poly-anionic / Prussian-blue family), aluminium-shell cell
Nominal capacity13.5 Ah
Nominal energy42.1 Wh
Nominal voltage3.12 V
Voltage range2.0 – 3.6 V (LFP-like curve, 2 V cut-off)
15C capacity retention97.1%
Rate capability0.33C 100.5% · 0.5C 100.4% · 1C 100% · 5C 98.0% · 10C 96.6% · 15C 97.1%
High/low-temperature retention45 °C 102% · 25 °C 100% · 0 °C 93% · -20 °C 86.4% · -40 °C 76.5% · -50 °C 74.3%
Low-temperature operationUsable to -50 °C (2 V cut-off)
Cycle life2,000 cycles @100% DOD, 1C/1C, 70% SOH
StructureAluminium shell & lid, dual large-area aluminium terminals (weld depth ≥2 mm), dual safety vents, full-tab jellyroll
Safety certificationGB 38031 third-party tested (CATARC Tianjin): over-discharge, over-charge, external short circuit, heating, thermal cycle, crush — all PASS

Confirm the current model specification and applicable test conditions before system approval. Charging, discharging and storage limits are separate requirements.

Built for start-stop duty

The RPA13 pairs an aluminium shell and lid with dual large-area terminals and a full-tab jellyroll for low internal resistance, even current distribution and high continuous over-current capability. Dual safety vents add redundancy for start-stop and high-rate applications.

Rate discharge capacity retention

Rate0.33C0.5C1C5C10C15C
Capacity retention100.5%100.4%100%98.0%96.6%97.1%

Capacity retention vs temperature

Temperature45 °C25 °C0 °C-20 °C-40 °C-50 °C
Capacity retention102%100%93%86.4%76.5%74.3%

What to include in an enquiry

Include this model, your application, quantity, destination and required delivery date. For a starter replacement, include the original battery reference and vehicle details. For a cell integration, include your pack voltage, current and thermal design.

Discuss your battery requirements

Send the application, required specifications, quantity and destination for a model-specific proposal.

Request a quote