SIB 26700 Sodium-ion Cell — 3.2 Ah / 3.5 Ah
The 26700 sodium-ion cylindrical cell is offered in two independently specified capacity versions: a 3.2 Ah version (≈3.10 V, 3.95 V charge limit, 30C continuous / 50C pulse) and a 3.5 Ah version, model NaCR26700-ME35 (3.0 V, -40 ~ 60 °C window, ≥ 3,000 cycles at 70% retention). Both specification sheets are reproduced below in full — values are never merged or averaged.
Two capacity versions, two specification sheets
The 26700 sodium-ion cell is supplied in two capacity versions, each backed by its own specification sheet. The 3.2 Ah and 3.5 Ah cells differ in nominal voltage, charge limit, weight, impedance and current ratings, so pack designers should treat them as separate models. The table below summarises the key differences; complete datasheets for each version follow.
| Parameter | 3.2 Ah version | 3.5 Ah version (NaCR26700-ME35) |
|---|---|---|
| Nominal capacity | 3.20 Ah (typical 3.25 Ah) @0.5C, 25.0 ± 3.0 °C | 3.5 Ah @0.5C, 25 ± 2 °C |
| Nominal voltage | ≈ 3.10 V | 3.0 V |
| Charge upper limit | 3.95 ± 0.05 V | 4.0 V |
| Discharge lower limit | 1.50 ± 0.05 V (0 V discharge allowed) | 1.5 V |
| Weight | 84.00 ± 2.00 g | 85 ± 1 g |
| Impedance | DC ≤ 20.00 mΩ | AC ≤ 20 mΩ · DC ≤ 60 mΩ |
| Dimensions | Ø26.40 ± 0.10 × 71.00 ± 0.15 mm | Ø26.4 ± 0.15 × 70.7 ± 0.10 mm |
| Max. continuous discharge | 30.00 C | 10.5 A (3C) |
| Cycle life | Not stated on specification sheet — confirm with us for your duty cycle | ≥ 3,000 cycles at ≥ 70% retention |
3.2 Ah version — technical specifications
| Model | 26700 (3,200 mAh version), specification sheet rev. A1 dated 2023-10-06 |
|---|---|
| Nominal capacity | 3.20 Ah @0.5C, 25.0 ± 3.0 °C (typical 3.25 Ah) |
| Nominal voltage | ≈ 3.10 V |
| Charge upper-limit voltage | 3.95 ± 0.05 V |
| Discharge lower-limit voltage | 1.50 ± 0.05 V (discharge to 0 V does not affect performance) |
| DC internal impedance | ≤ 20.00 mΩ |
| Cell dimensions | Ø26.40 ± 0.10 mm × 71.00 ± 0.15 mm |
| Weight | 84.00 ± 2.00 g |
| Energy density | ≥ 120.00 Wh/kg |
| Max. continuous discharge | 30.00 C (temperature rise ≤ 30 °C) |
| Max. instantaneous discharge | 50.00 C, ≤ 30 s |
| Rate performance | 1.0C discharge capacity / 0.5C ≥ 98.00% @25 °C |
| Charge temperature profile | ≤ -20 °C not recommended; -20 ~ 0 °C ≤ 0.20C; 0 ~ 45 °C ≤ 0.50C; ≥ 45 °C not recommended |
| Discharge temperature profile | ≤ -40 °C not recommended; -40 ~ 0 °C ≤ 0.20C; 0 ~ 45 °C 0.20 ~ 3.0C; 45 ~ 60 °C ≤ 0.20C; ≥ 60 °C not recommended |
| Shipping / storage condition | Charged state, -20 ~ 60 °C, 65 ± 20% RH, shaded and ventilated |
| Safety tests | Vibration / heating / external short circuit / overcharge / overdischarge / heavy object impact / drop / crush / low pressure per UL1642, GB 38031, GB/T 31485 — no fire, no explosion, no leakage |
3.5 Ah version (NaCR26700-ME35) — technical specifications
| Model | NaCR26700-ME35, doc. no. HNXN-SPE-007, version V0 (2024-04-27) |
|---|---|
| Rated capacity | 3.5 Ah (0.5C discharge, 25 ± 2 °C) |
| Nominal voltage | 3.0 V |
| Charge cut-off voltage | 4.0 V (T: 0 ~ +60 °C) |
| Discharge cut-off voltage | 1.5 V (T: -40 ~ +60 °C) |
| AC impedance | ≤ 20 mΩ (1 kHz, 3.2 V) |
| DC impedance | ≤ 60 mΩ (3C 10 s, 3.2 V) |
| Standard charge | 0.25C CC to 4.0 V, CV to 0.05C |
| Standard discharge | 0.25C DC to 1.5 V |
| Max. continuous charge / discharge | 7.0 A (2C) / 10.5 A (3C) |
| Cell dimensions | Ø26.4 ± 0.15 mm × 70.7 ± 0.10 mm |
| Weight | 85 ± 1 g |
| Charge / discharge temperature | 0 ~ +60 °C / -40 ~ +60 °C (65 ± 20% RH) |
| Storage temperature | 10 ~ +40 °C (1 month); 10 ~ +30 °C (6 months), 25 ~ 85% RH |
| High-temperature discharge | ≥ 95% of initial capacity (3.325 Ah), 55 ± 2 °C, 1I2 discharge |
| Low-temperature discharge | ≥ 80% of initial capacity (2.8 Ah), -20 ± 2 °C, rest ≥ 16 h |
| Rate performance | ≥ 90% of initial capacity (3.15 Ah), 2I2 CC discharge |
| Low-temperature charge | ≥ 80% of initial capacity (2.8 Ah), -10 ± 2 °C, 0.1I1 charge |
| Cycle life | ≥ 3,000 cycles at ≥ 70% retention (2.45 Ah), 1I2 charge/discharge per T/CIAPS 0031-2023 |
| Charge retention / recovery | Room temp 28 days: ≥ 85% (2.975 Ah) kept / ≥ 90% (3.15 Ah) recovered; 55 ± 2 °C 7 days: ≥ 85% / ≥ 90% |
| Safety tests | Short circuit / overcharge / overdischarge / drop / heavy impact / crush / heating per T/CIAPS 0031-2023 6.2.4.x — no fire, no explosion, no leakage |
Measured low-temperature discharge (3.5 Ah version)
| Test | Condition | Result |
|---|---|---|
| 1C discharge at -40 °C | Two-cell sample average | 83.3% of room-temperature capacity (measured) |
Specification-sheet low-temperature requirement is ≥ 80% at -20 °C; the -40 °C figure above is measured test data, not a specification guarantee.
Choosing between the two versions
For power-duty packs that need the widest current headroom and verified -40 °C behaviour, the 3.5 Ah NaCR26700-ME35 is the reference cell. For designs specified around a ≈3.10 V platform with 3.95 V charge limit and high rate discharge (30C continuous), the 3.2 Ah version fits. Both are cylindrical 26700 sodium-ion cells and are not interchangeable with 26650 cells of different diameter and capacity.
What to include in an enquiry
State which capacity version (3.2 Ah or 3.5 Ah) you are evaluating, along with your application, pack voltage and current targets, quantity and destination. For pack integration, include your BMS current limits and thermal design so we can confirm cell suitability.
Discuss your battery requirements
Send the application, required specifications, quantity and destination for a model-specific proposal.
Request a quote