Skip to content
HomeAbout usProductsResourcesBlog Contact
NaCR26650-25UT — 3.0 V 2.5 Ah 26650 Sodium-Ion Cell (Low-Temperature High-Rate)
Sodium-ion cells

NaCR26650-25UT — 3.0 V 2.5 Ah 26650 Sodium-Ion Cell (Low-Temperature High-Rate)

A 26650 cylindrical sodium-ion cell built for cold-start and pulse duty. It delivers 2.5 Ah at 3.0 V with 20C continuous and 70C 3-second pulse discharge, retains ≥75% of its 25 °C capacity at -40 °C, and is rated for 2,000 cycles at 3C/3C. Data from Veken specification VKB-QS-SPE-3014 (A0, 4 November 2025).

2.5 Ah · 3.0 V70C pulse (3 s)≥75% capacity at -40 °C2,000 cycles @ 3C/3C
Request a quote

Technical specifications

Cell format26650 cylindrical sodium-ion cell
DimensionsΦ26.2 ±0.2 mm (with PET film) × 65 ±0.5 mm
Nominal voltage3.0 V
Typical capacity2.50 Ah · minimum 2.45 Ah (0.2C, 25 ±2 °C)
Weight74 ±5 g
Max. continuous charge3C @ 100% SOC · 6C @ 90% SOC (25 °C) · 0.5C at -20 ~ -15 °C · ≤6C at 25 ~ 45 °C
Max. continuous discharge20C (25 °C) · ≤25C at -10 ~ 25 °C · ≤15C at -20 ~ -10 °C · ≤5C at -40 ~ -30 °C · ≤5C at 45 ~ 75 °C
Max. peak discharge70C (3 s pulse, >1.8 V)
Max. pulse cycle discharge25C (3 s pulse)
Rate discharge capacity0.5C ≥97% · 1C ≥95% · 5C ≥92% · 10C ≥90% · 15C ≥88% · 20C ≥85%
Cycle life (25 °C)1C/1C 2,000 cycles ≥80% · 3C/3C 2,000 cycles ≥80%
Pulse cycle life3C charge / 20C 3 s pulse: 2,000 cycles, energy ≥70% (50,000 pulses)
Low-temperature cycling-10 °C 3C/3C 600 cycles ≥60% · -15 °C 3C/3C 100 cycles ≥70%
High-temperature cycling75 °C 3C/3C 1,000 cycles, energy ≥60%
Standard charge0.5C CC-CV to 3.9 V (cut-off 125 mA)
Max. charge voltage3.95 V
Discharge cut-off voltage1.5 V
Storage temperature-20 ~ 75 °C (1 month) · 0 ~ 45 °C (3 months) · 0 ~ 25 °C (1 year)
Shipping SOC20 – 70%
Storage performance30 days @ 25 °C: retention ≥90%, recovery ≥95% · 30 days @ 60 °C: retention ≥80%, recovery ≥90%

Source: Veken Technology product specification VKB-QS-SPE-3014, revision A0, dated 4 November 2025. Values are BOL measurements at 25 ±2 °C unless stated otherwise. Confirm the current datasheet revision before design approval.

Key performance highlights

  • 70C 3-second peak discharge at ≥1.8 V (25 °C, 90% SOC)
  • 20C maximum continuous discharge (not for cycling)
  • 25C 3-second pulse discharge rated for pulse cycling
  • Low-temperature charging from -20 °C (rate-limited) and discharge down to -40 °C
  • 2,000 cycles at 1C/1C and 3C/3C with ≥80% capacity retention
  • 2,000 pulse cycles at 3C charge / 20C pulse with ≥70% energy retention (50,000 pulses)

Rate discharge capability @ 25 °C

After a standard charge to 3.9 V and a 30-minute rest, the cell is discharged at each rate to 1.5 V. Capacity is expressed relative to the 0.2C result.

0.2C100% (reference)
0.5C≥ 97%
1C≥ 95%
5C≥ 92%
10C≥ 90%
15C≥ 88%
20C≥ 85%

Discharge capacity vs temperature (1C)

Standard charge at 25 ±2 °C, then 12 h soak at sub-zero temperatures (4 h at 25 °C / 75 °C) and 1C discharge to 1.5 V. The 25 °C result is the 100% reference.

Cell temperatureCapacity retention vs 25 °C
-40 °C≥ 75%
-30 °C≥ 80%
-20 °C≥ 85%
-10 °C≥ 90%
0 °C≥ 92%
25 °C100% (reference)
75 °C≥ 95%

Cold-cranking reference: after a 24 h soak at -18 ±1 °C, a 20C constant-current discharge holds ≥1.8 V minimum voltage over the first 10 seconds.

Standard test methods

Standard charge (25 ±2 °C): 0.5C constant current to 3.9 V, then constant voltage until current falls to 125 mA. Maximum charge voltage 3.95 V; maximum continuous charge 3C at 100% SOC or 6C at 90% SOC (25 °C).

Standard discharge (25 ±2 °C): 0.2C constant current to 1.5 V cut-off.

Cycle life: 1C or 3C CC charge to 3.65 V, CV to 0.05C, rest 10–30 min; 1C or 3C CC discharge to 2.0 V, rest 30 min. Capacity retention ≥80% after 2,000 cycles.

Pulse cycling: 3C CC-CV charge to 3.65 V, rest 30 min; 20C discharge for 3 s, rest 5 s, repeated 26 times, then rest 60 min — repeated for 2,000 cycles (≈50,000 pulses) with ≥70% energy retention.

Cycle life and pulse duty

The 25UT is specified for both energy cycling and pulse duty. At 25 °C it holds ≥80% capacity after 2,000 cycles at either 1C/1C or 3C/3C in the 2.0–3.65 V window. Under a starting-style pulse profile (3C charge, 20C 3-second discharge pulses), it completes 2,000 cycles — roughly 50,000 pulses — while retaining ≥70% of initial energy.

Cold-weather endurance is specified separately: 600 cycles at -10 °C (3C/3C) retain ≥60% capacity and 100 cycles at -15 °C retain ≥70%. At 75 °C, 1,000 cycles at 3C/3C retain ≥60% energy. These are specification limits under defined test methods, not a universal lifetime guarantee — validate against your own duty cycle.

Safety and reliability

The specification requires no fire and no explosion in over-discharge (1C, 90 min), overcharge (3C to 10 V), external short circuit (80 ±20 mΩ, 10 min), 130 °C hot-box exposure (30 min), crush, 1.0 m drop and impact testing. Cells are supplied at 20–70% SOC and should be integrated with a BMS that enforces the voltage, current and temperature limits in the specification.

Typical applications

Engine starting and start-stop buffer packs, emergency start power, actuator and pulse-power modules, cold-chain and outdoor equipment operating below -20 °C, hybrid power buffers and UPS modules that need high burst current in a compact 26650 format.

What to include in an enquiry

State the model, application, quantity, destination and required delivery date. For pulse duty include the pulse profile (current, duration, rest interval and SOC window) and the ambient temperature range so the power capability and low-temperature limits can be checked against your duty cycle.

Discuss your battery requirements

Send the application, required specifications, quantity and destination for a model-specific proposal and datasheet.

Request a quote

Compare related sodium-ion cells